12 Strand, OCC BX Series Breakout, Indoor/Outdoor, OFNR Riser, Singlemode 9/125
Reference Previous Part Number:BX12-140D-SLX/900-OFNR
Note: This item may require 24 hours for cut and prep before shipping.
 
CABLE CHARACTERISTICS: B-SERIES BREAKOUT RISER CABLES (WITH 2.5MM SUBCABLES)
|   | 
Tensile Load | 
Menimum Bend Radius | 
|   | 
Diameter | 
Weight | 
Installation | 
Operational | 
Installation | 
Long Term | 
| Fiber Count | 
Part Number | 
mm/(in) | 
kg/km (lbs/1,000) | 
N (lbs) | 
N (lbs) | 
cm (in) | 
cm (in) | 
| 12 | 
BX012DSLX9KR | 
13.0 (0.51) | 
142 (95) | 
6,000 (1,350) | 
2,500 (560) | 
19.5 (7.7) | 
13.0 (5.1) | 
 
 
 
BREAKOUT SERIES FIBER OPTIC CABLE TYPE OFNR RISER PRODUCT SPECIFICATIONS
Applications
- Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary
 
- Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired
 
Features
- High performance components and construction
 
- UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
 
- Most rugged and easy to install cable design for enterprise cabling applications
 
- Core-Locked™ outer jacket design for installation survivability, long-term, trouble free service
 
- Ideal for use in long, vertical installations
 
- 2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)
 
- Subcabled fiber is environmentally and mechanically protected
 
- Ideal for use in point-to-point runs in adverse environments
 
- Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
 
- Design is ideal for direct pulling with mesh grips
 
- Cable materials are Indoor/Outdoor UV, water and fungus resistant
 
- Wide operating temperature range of -40°C to +85°C
 
- High performance 900 µm tight-buffered coating on each optical fiber for environmental and mechanical protection
 
- Interlocking armor can be applied to cables as an alternative to conduit installation
 
Cost savings
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber. See page PI-6 for typical termination approach.
 
- Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
 
- High crush resistance may eliminate the need for innerduct
 
Mechanical and Environmental Performance
|   | 
Indoor/Outdoor | 
| Operating Temperature | 
-40°C to +85°C | 
| Storage Temperature | 
-55°C to +85°C | 
| Installation Temperature (cable temp.) | 
-10°C to +60°C | 
| Flame Retardancy | 
UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) | 
| Impact Resistance | 
1,500 impacts | 
| Crush Resistance | 
2,200 N/cm | 
| Flex Resistance | 
2,000 Cycles | 
Note: Optical Cable Corporation reserves the right to change this specification without prior notification.