OCC, DX, Distribution Series, 2-Strand, 900um Tight Buffered, Indoor/Outdoor,OFNR Rated, OS2, 9/125, Singlemode, Yellow Jacket
Reference Previous Part Number: DX02-045D-SLX/900-OFNR
Note: This item may require 24 hours for cut and prep before shipping.
DX-Series Distribution – Riser Rated Cables
Installation zone RECOMMENDATION
- Indoor/Outdoor tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types
- Ideal configuration for a single termination point requiring multiple fibers
- 900μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices, because connectors terminate directly to the fiber
- No need to splice outdoor cable to indoor cable at building entrance
- High crush resistance may eliminate the need for innerduct
Applications
- Indoor/Outdoor tight-bound tight-buffered design allows cables to be installed in intra-building backbone and inter-building campus locations without costly transitions between cable types
- Ideal configuration for a single termination point requiring multiple fibers
COST SAVINGS
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
- No need to splice outdoor cable to indoor cable at building entrance
- High crush resistance may eliminate the need for innerduct
 
Features
- High performance components and construction
- Cable materials are indoor/outdoor - UL-listed OFNR and UV, water and fungus resistant
- UL Listed in accordance with NEC section 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
- Wide operating temperature range of -40°C to +85°C
- Helically stranded core for greater flexibility and mechanical protection of the optical fibers
- High strength-to-weight ratio
- 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables made by others: ideal for installation in areas with limited space or tight bends
- Can be armored for additional protection in direct burial and aerial installations
- Interlocking armor can be applied to cables as an alternative to conduit installation
Characteristics
| Characteristic | Riser | 
| Operating Temp | -40°C to +85°C | 
| Storage Temp | -55°C to +85°C | 
| Install Temp | -10°C to +60°C | 
| Flame Retardancy | UL listed type OFNR (UL 1666) for all fiber counts *FT4 (CSA C22.2 No. 232) for 2-24 fiber counts only | 
| Crush Resist | 1800 N/cm | 
| Impact Resist | 1500 impacts | 
| Flex Resist | 2000 cycles | 
| Jacket Type | D | 
Standards
Optical Cable Corporation's Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
- UL 1651
- UL 1666
- GR-409-CORE
- ICEA-S-104-696
- ICEA-S-83-596
- TIA-568
- TIA-598
- UL-listed type OFNR in accordance with NEC sections 770-179 (B) and 770-154 (B) for use in vertical runs in building riser shafts or from floor to floor. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
Specifications
Riser
|  | Tensile Load | Minimum Bend Radius |  | 
| Fiber Count | Part Number | Diameter mm (in)
 | Weight kg/km (lbs/1,000ft)
 | Installation N (lbs)
 | Operation N (lbs)
 | Installation cm (in)
 | Longer Term cm (in)
 |  | 
| 2 | DX002DSLX9YR | 4.8 (0.19)
 | 22.0 (14.0)
 | 660 (150)
 | 180 (40)
 | 7.3 (2.9)
 | 4.8 (1.9)
 |  | 
| 4 | DX004D***9*R | 5.1 (0.20)
 | 24.0 (16.0)
 | 1,400 (310)
 | 450 (100)
 | 7.7 (3.0)
 | 5.1 (2.0)
 |  | 
| 6 | DX006D***9*R | 5.7 (0.22)
 | 31.0 (21.0)
 | 1,400 (310)
 | 450 (100)
 | 8.6 (3.4)
 | 5.7 (2.2)
 |  | 
| 8 | DX008D***9*R | 6.0 (0.24)
 | 33.0 (22.0)
 | 1,600 (360)
 | 525 (120)
 | 9.0 (3.5)
 | 6.0 (2.4)
 |  | 
| 10 | DX010D***9*R | 6.5 (0.26)
 | 42.0 (28.0)
 | 1,800 (400)
 | 600 (135)
 | 9.8 (3.9)
 | 6.5 (2.6)
 |  | 
| 12 | DX012D***9*R | 6.5 (0.26)
 | 38.0 (25.0)
 | 2,700 (600)
 | 600 (135)
 | 9.8 (3.9)
 | 6.5 (2.6)
 |  | 
| 18 | DX018D***9*R | 7.3 (0.29)
 | 47.0 (31.0)
 | 2,700 (600)
 | 700 (160)
 | 11.0 (4.3)
 | 7.2 (2.8)
 |  | 
| 24 | DX024D***9*R | 8.9 (0.35)
 | 66.0 (44.0)
 | 3,000 (670)
 | 1,000 (220)
 | 13.4 (5.3)
 | 8.9 (3.5)
 |  | 
| 30 | DX030D***9*R | 9.1 (0.36)
 | 75.0 (50.0)
 | 3,000 (670)
 | 1,000 (220)
 | 13.7 (5.4)
 | 9.1 (3.6)
 |  | 
| 36 | DX036D***9*R | 9.1 (0.36)
 | 73.0 (49.0)
 | 3,000 (670)
 | 1,000 (220)
 | 13.7 (5.4)
 | 9.1 (3.6)
 |  | 
| 48 | DX048D***9*R | 10.5 (0.41)
 | 93.0 (63.0)
 | 4,200 (940)
 | 1,400 (310)
 | 17.4 (6.9)
 | 11.6 (4.6)
 |  | 
| 60 | DX060D***9*R | 12.3 (0.48)
 | 135.0 (91.0)
 | 4,800 (1,080)
 | 1,600 (360)
 | 18.5 (7.3)
 | 12.3 (4.8)
 |  | 
| 72 | DX072D***9*R | 14.0 (0.55)
 | 177.0 (119.0)
 | 5,400 (1,210)
 | 1,800 (400)
 | 21.0 (8.3)
 | 14.0 (5.5)
 |  | 
| 84 | DX084D***9*R | 14.4 (0.57)
 | 190.0 (128.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 21.6 (8.5)
 | 14.4 (5.7)
 |  | 
| 96 | DX096D***9*R | 16.0 (0.63)
 | 225.0 (151.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 24.1 (9.5)
 | 16.0 (6.3)
 |  | 
| 108 | DX108D***9*R | 16.8 (0.66)
 | 246.0 (165.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 25.3 (10.0)
 | 16.8 (6.6)
 |  | 
| 120 | DX120D***9*R | 17.9 (0.70)
 | 271.0 (182.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 26.8 (10.6)
 | 17.9 (7.0)
 |  | 
| 132 | DX132D***9*R | 17.8 (0.70)
 | 291.0 (195.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 26.8 (10.6)
 | 17.8 (7.0)
 |  | 
| 144 | DX144D***9*R | 20.3 (0.80)
 | 339.0 (228.0)
 | 6,000 (1,350)
 | 2,000 (450)
 | 30.5 (12.0)
 | 20.3 (8.0)
 |  | 