Part Number: DX006TWLS9OP
OCC, DX, Distribution Series, 6-Strand, 900um Tight Buffered, Indoor/Outdoor, OFNP Plenum Rated, OM1, 62.5/125, Multimode, Orange Jacket
Applications
- Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces
- Ideal configuration for a single termination point requiring multiple fibers
- Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments
Features
- UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
- Low-smoke PVC jacket
- 2 to 24 fibers
- Cable materials are Indoor/Outdoor UL-Listed OFNP and also UV, water and fungus resistant
- High performance tight-buffered coating on each fiber for environmental and mechanical protection
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
- Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
- High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls
- High crush resistance may eliminate the need for innerduct
- Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments
- Interlocking armor can be applied to cables as an alternative to conduit installation
Characteristics
Characteristic |
Plenum Indoor/Outdoor (K) |
Operating Temp |
-40°C to +70°C |
Storage Temp |
-40°C to +70°C |
Install Temp |
0°C to +60°C |
Flame Retardancy |
UL Listed Type OFNP NFPA262 FT6 (CSA C22.2 No. 232) |
Crush Resist |
1500 N/cm (TIA/EIA-455-41A) |
Impact Resist |
1000 impacts (EIA/TIA-455-25A) |
Flex Resist |
1000 cycles (TIA/EIA-455-104A) |
Jacket Type |
K |
Standards
Optical Cable Corporation Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
- UL 1651
- ANSI/NFPA 262
- GR-409-CORE
- ICEA-S-104-696
- ICEA-S-83-596
- TIA-568
- TIA-598
- UL-listed type OFNP in accordance with NEC sections 770-179 (A) and 770-154 (A) for use in ducts, plenums, and air-handling spaces. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.
Specifications
Plenum Indoor/Outdoor (T)
|
Tensile Load |
Minimum Bend Radius |
|
Fiber Count |
Part Number |
Diameter mm (in) |
Weight kg/km (lbs/1,000ft) |
Installation N (lbs) |
Operation N (lbs) |
Installation cm (in) |
Longer Term cm (in) |
|
2 |
DX002T***9*P |
3.8 (0.15) |
15.0 (10.0) |
1,400 (150) |
180 (40) |
5.7 (2.2) |
3.8 (1.5) |
|
4 |
DX004T***9*P |
4.5 (0.18) |
18.0 (12.0) |
1,200 (270) |
400 (50) |
6.7 (2.6) |
4.5 (1.8) |
|
6 |
DX006TWLS9OP |
4.7 (0.19) |
18.0 (12.0) |
1,400 (310) |
450 (100) |
7.1 (2.8) |
4.7 (1.9) |
|
8 |
DX008T***9*P |
5.7 (0.22) |
37.0 (25.0) |
1,600 (360) |
525 (120) |
8.6 (3.4) |
5.7 (2.2) |
|
10 |
DX010T***9*P |
6.1 (0.24) |
44.0 (29.0) |
1,800 (400) |
600 (135) |
9.1 (3.6) |
6.1 (2.4) |
|
12 |
DX012T***9*P |
6.2 (0.24) |
40.0 (27.0) |
1,800 (400) |
600 (135) |
9.3 (3.7) |
6.2 (2.4) |
|
18 |
DX018T***9*P |
6.7 (0.26) |
40.0 (29.0) |
1,800 (400) |
600 (135) |
10.1 (4.0) |
6.7 (2.6) |
|
24 |
DX024T***9*P |
8.1 (0.32) |
66.0 (44.0) |
3,000 (670) |
1,000 (220) |
12.2 (4.8) |
8.1 (3.2) |
|