close
close

OCC, DX Series, 36-Strand, 900um Tight Buffd, I/O, Chemical Resistant OFNP , OS2, SM, Yellow ( Per Foot)

click to zoom in

OCC, DX Series, 36-Strand, 900um Tight Buffd, I/O, Chemical Resistant OFNP , OS2, SM, Yellow ( Per Foot)

Item#:
DX036KSLA9YP
List Price: $3.60
$3.26
(You save $0.34 )
Condition:
New
Weight:
0.06 LBS
Minimum Purchase:
1000 units
Bulk Pricing:
Buy in bulk and save
Customer Service

Need Help?

Speak to one of our experts.

OCC, DX Series, 36-Strand, 900um Tight Buffd, I/O, Chemical Resistant OFNP , OS2,  SM, Yellow

OCC, DX Series, 36-Strand, 900um Tight Buffd, I/O, Chemical Resistant OFNP , OS2, SM, Yellow ( Per Foot)

List Price: $3.60
$3.26
(You save $0.34 )
⚠️ California Proposition 65 Warning: Some products sold on this site may contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. Learn more: P65Warnings.ca.gov

OCC, DX, Distribution Series, 36-Strand, 900um Tight Buffered, Indoor/Outdoor, Chemical Resistant OFNP Plenum Rated, OS2, 9/125, Singlemode, Yellow Jacket

Installation Zone Recommendation

Applications

  • Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces
  • Ideal configuration for a single termination point requiring multiple fibers
  • Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments

Features

  • UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
  • Fluorpolymer jacket
  • 2 to 72 fibers
  • Cable materials are Indoor/Outdoor UL-Listed OFNP and also UV, chemical, water and fungus resistant
  • Jacket is highly chemical resistant for installation in harsh industrial environments
  • High performance tight-buffered coating on each fiber for environmental and mechanical protection
  • 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
  • Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
  • High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls
  • High crush resistance may eliminate the need for innerduct
  • Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments
  • Interlocking armor can be applied to cables as an alternative to conduit installation

Indoor/Outdoor ("K" Jacket)

  • Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments
  • Cable materials are UV, water and fungus resistant
  • Higher fiber counts available than similar cables available by others in subgrouped configuration
  • Jacket is highly chemical resistant for installation in harsh industrial environments
  • Interlocking armor can be applied to cables as an alternative to conduit installation
  • Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments
  • 2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends

Standards

Optical Cable Corporation Indoor/Outdoor tight buffered fiber optic cables meet the functional requirements of the following standards:

  • UL 1651
  • ANSI/NFPA 262
  • GR-409-CORE
  • ICEA-S-104-696
  • ICEA-S-83-596
  • TIA-568
  • TIA-598
  • UL-listed type OFNP in accordance with NEC sections 770-179 (A) and 770-154 (A) for use in ducts, plenums, and air-handling spaces. Meets or exceeds requirements for intra-building fiber optic cables as outlined in GR-409-CORE.

Characteristics

Characteristic Plenum Indoor/Outdoor (K)
Operating Temp -40°C to +85°C
Storage Temp -40°C to +85°C
Install Temp 0°C to +60°C
Flame Retardancy UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232)
Crush Resist 1500 N/cm (TIA/EIA-455-41A)
Impact Resist 1000 impacts (EIA/TIA-455-25A)
Flex Resist 1000 cycles (TIA/EIA-455-104A)
Jacket Type K

Specifications

Plenum Indoor/Outdoor (K)

  Tensile Load Minimum Bend Radius
Fiber Count Part Number Part Number Configurator Diameter mm
(in)
Weight kg/km
(lbs/1,000ft)
Installation N
(lbs)
Operation N
(lbs)
Installation cm
(in)
Longer Term cm
(in)
 
2 DX002K***9*P   4.8
(0.19)
24.0
(16.0)
1,400
(310)
450
(100)
7.2
(2.8)
7.2
(2.8)
 
4 DX004K***9*P   4.8
(0.19)
24.0
(16.0)
1,400
(310)
450
(100)
7.2
(2.8)
7.2
(2.8)
 
6 DX006K***9*P   4.8
(0.19)
24.0
(16.0)
1,400
(310)
450
(100)
7.2
(2.8)
7.2
(2.8)
 
8 DX008K***9*P   5.1
(0.20)
30.0
(20.0)
1,600
(360)
525
(120)
7.7
(3.0)
7.7
(3.0)
 
10 DX010K***9*P   5.7
(0.22)
38.0
(26.0)
1,800
(400)
600
(135)
8.6
(3.4)
8.6
(3.4)
 
12 DX012K***9*P   6.5
(0.26)
45.0
(30.0)
2,700
(600)
900
(200)
9.8
(3.9)
9.8
(3.9)
 
18 DX018K***9*P   6.5
(0.26)
42.0
(28.0)
2,700
(600)
900
(200)
9.8
(3.9)
9.8
(3.9)
 
24 DX024K***9*P   8.3
(0.33)
71.0
(46.0)
3,000
(670)
1,000
(220)
11.8
(4.6)
11.8
(4.6)
 
30 DX030K***9*P   8.2
(0.32)
81.0
(53.0)
3,000
(670)
1,000
(220)
12.4
(4.9)
12.4
(4.9)
 
36 DX036K***9*P   8.3
(0.33)
80.0
(53.0)
3,000
(670)
1,000
(220)
12.4
(4.9)
12.4
(4.9)
 
48 DX048K***9*P   9.6
(0.38)
104.0
(70.0)
4,200
(940)
1,400
(310)
14.3
(5.6)
14.3
(5.6)
 
60 DX060K***9*P   10.7
(0.42)
129.0
(87.0)
4,800
(1,080)
1,600
(360)
16.1
(6.3)
16.1
(6.3)
 
72 DX072K***9*P   12.6
(0.50)
175.0
(122.0)
5,400
(1,200)
1,800
(400)
19.6
(7.7)
19.6
(7.7)
 

Reference Previous Part Number:DX36-075K-SLX/900-OFNP