CyberPower
Speak to one of our experts.
A rackmount UPS with line interactive topology, the CyberPower Smart App LCD OR700LCDRM1U provides battery backup (using simulated sine wave output) and surge protection for department servers, workgroup servers, workstations, network devices, and telecom installations without active PFC power supplies. The OR700LCDRM1U uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. The OR700LCDRM1U comes with a three-year warranty and a $300,000 Connected Equipment Guarantee.
UPS System, Rackmount Brackets x 2, USB A+B Type Cable, User Manual
WARNING:
This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm.
General | |
---|---|
Energy Saving | GreenPower UPS™ Bypass Technology |
Energy Star Certified | Yes |
UPS Topology | Line Interactive |
Battery | |
Battery Quantity | 2 |
Battery Size | 6 V / 8 Ah |
Battery Type | Sealed Lead-Acid Battery |
Hot Swappable | Yes |
Replacement Battery Cartridge | RB0690X2 |
Replacement Battery Cartridge Quantity | 1 |
Runtime at Full Load | 3 min |
Runtime at Half Load | 11 min |
Typical Recharge Time | 8 Hours |
User Replaceable Battery | Yes |
Input | |
Adjustable Voltage Range | 88 – 144 VAC |
Circuit Breaker | 15A |
Cord Length | 10 ft (3 m) |
Input Frequency Range | 57 Hz – 63 Hz |
Input Plug Type | NEMA 5-15P |
Input Voltage Range | 90 VAC – 140 VAC |
Nominal Input Voltage | 120 VAC |
Plug Style | Straight |
Output | |
Automatic Voltage Regulation | Single Boost |
On Battery Frequency | 60 Hz ± 1% |
On Battery Voltage | 120 VAC ± 10% |
On Battery Waveform | Simulated Sine Wave |
Outlet Type | NEMA 5-15R |
Outlets – Battery & Surge Protected | 4 |
Outlets – Surge-Only Protected | 2 |
Outlets – Total | 6 |
Output Power Factor | 0.6 |
Overload Protection | Internal Circuitry Limiting Circuit Breaker Protected |
Typical Transfer Time | 8 ms |
VA | 700 VA |
Watts | 400 W |
Surge Protection & Filtering | |
EMI/RFI Filtration | Yes |
Network Protection RJ45 | 1-in / 1-Out (10/100/1000) |
Surge Suppression (Joules) | 1150 J |
Management & Communications | |
Audible Alarms | Battery Mode Low Battery Overload Fault |
HID Compliant USB Port | Yes |
LCD | Multifunction LCD |
LED Indicators | Power On Wiring Fault |
Management Cable | USB Cable |
SNMP / HTTP Remote Monitoring | Yes – with optional RMCARD205 |
Serial Port | 1 Dry Contact |
Software (Free Download) | PowerPanel® Business |
Physical | |
Form Factor | Rackmount |
Material of Construction | Metal |
Rack Height | 1U |
Dimensions | |
Physical Dimensions – (WxHxD) (cm) | 43.31 x 4.45 x 23.5 (cm) |
Physical Dimensions – (WxHxD) (in) | 17.05 x 1.75 x 9.25 (in) |
Physical Dimensions – (WxHxD) (mm) | 433 x 44 x 235 (mm) |
Weight (kg) | 8.39 |
Weight (lb) | 18.5 |
Dimensions – Shipping | |
Shipping – Weight (kg) | 9.89 |
Shipping – Weight (lb) | 21.8 |
Shipping Dimensions – (WxHxD) (cm) | 31.75 x 14.61 x 52.07 (cm) |
Shipping Dimensions – (WxHxD) (in) | 12.5 x 5.75 x 20.5 (in) |
Shipping Dimensions – (WxHxD) (mm) | 317.5 x 146.05 x 520.7 (mm) |
Environmental | |
Operating Elevation | 0 – 10000 ft (0 – 3048 m) |
Operating Relative Humidity | 0 – 95 % (non-condensing) |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Storage Elevation | 0 – 50000 ft (0 – 15239 m) |
Storage Relative Humidity | 0 – 95% (non-condensing) |
Storage Temperature | 5 – 113 °F (-15 – 45 °C) |
Certifications | |
Environmental | RoHS Compliant |
Safety | UL1778 cUL107.1 FCC Class B |
Warranty | |
CEG Amount | $300000 |
Connected Equipment Guarantee | Lifetime |
Extended Warranty Option | WEXT5YR-U1B |
Product Warranty | 3 Year Limited Warranty |
The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel® Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).
Safe Shutdown
The PowerPanel® Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.
Programmable Outlet Control
Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.
GreenPower UPS™ Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.
Our patented Bypass Design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.
Automatic Voltage Regulation (AVR) in line interactive UPS systems stabilizes the incoming AC signal to maintain output power at a nominal 120 volts by controlling high and low voltages without resorting to battery power. This significantly increases battery life and lessens the likelihood of data loss, memory freezes, and system crashes.
How AVR Works in a Line Interactive UPS
A line interactive UPS includes an AVR autotransformer a special type of transformer designed to switch between powered coils of wire in response to variances in utility power input, thereby increasing or decreasing the magnetic field and the resulting output voltage to connected equipment.
This type of UPS tolerates undervoltage brownouts and overvoltage surges without consuming backup battery power by automatically selecting different power taps on the AVR autotransformer. During normal operation, incoming AC power bypasses the autotransformer (where voltage highs and lows are controlled) while also charging the battery. When the incoming voltage falls below the AVR range, the UPS switches to battery backup, and the DC-AC inverter circuitry is engaged. Power will continue to be supplied by the battery-inverter circuit until incoming voltage returns to the range manageable by the AVR.