Speak to one of our experts.
A rackmount UPS with line interactive topology, the CyberPower Smart App Sinewave PR750LCDRM1U provides battery backup, power protection (using sine wave output), and surge protection for corporate servers, department servers, storage appliances, network devices, and telecom installations requiring Active PFC power source compatibility. The PR750LCDRM1U uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. The PR750LCDRM1U comes with a three-year warranty (including coverage of batteries) and a Connected Equipment Guarantee.
UPS System, UPS User Manual, 2 Rack Mount Brackets, Emergency Power Off Cable (gray), PowerPanel Business Edition Software CD, Serial Interface Cable (RJ45/DB-9), USB A+B Type Cable, Warranty Registration Card
PowerPanel Business software download available here.
WARNING:
This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm.
General | |
---|---|
UPS Topology | Line Interactive |
Energy Saving | GreenPower UPS™ Bypass |
Input | |
Voltage | 80 – 150 VAC |
Frequency Range | 47 – 63 Hz |
Plug Type | NEMA 5-15P |
Plug Style | Right Angle, 45° Offset Right |
Cord Length | 10 ft |
Output | |
VA | 750 VA |
Watts | 560 W |
Automatic Voltage Regulation | Boost 1 +30%, Boost 2 +14% / Buck -12% |
On Battery Voltage | 120 VAC ± 5% |
On Battery Frequency | 50/60 Hz ± 1% |
On Battery Waveform | Sine Wave |
Outlet Type | NEMA 5-15R |
Outlets – Total | 6 |
Outlets – Critical Load | 2 |
Outlets – Battery & Surge Protected | 6 |
Overload Protection | Internal Circuitry Limiting
Circuit Breaker |
Transfer Time | 4 ms |
Battery | |
Runtime at Half Load | 23 minutes |
Runtime at Full Load | 7 minutes |
Battery Type | Sealed Lead-Acid |
Battery Size | 6V/9Ah |
Battery Quantity | 4 |
Hot-Swappable | Yes |
User Replaceable | Yes |
Replacement Battery Cartridge | RB0690X4A |
Replacement Battery Cartridge Quantity | 1 |
Typical Recharge Time | 8 hours |
Surge Protection & Filtering | |
Surge Suppression | 1,780 J |
Phone RJ11 / Ethernet RJ45 | None |
Coaxial Protection RG6 | None |
EMI/RFI Filtration | Yes |
Management & Communications | |
Multifunction LCD Panel | Displays:
Current/Load Level Runtime Battery Level Battery In Use Input Voltage Output Voltage Overload Silent Mode Normal Mode |
HID Compliant USB Port | Yes |
Serial Port | Yes |
Emergency Power Off (EPO) Port | Yes |
LED Indicators | Power On
Wiring Fault |
Audible Alarms | On Battery
Low Battery Overload |
Software | PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring | Yes, with optional RMCARD205 |
AS400 Management | None |
Physical | |
Rack Size | 1U |
Form Factor | Rack |
Dimensions – W×H×D (in) | 17.25 × 1.75 × 19.5 inches |
Weight (lbs) | 40.0 lbs |
Environmental | |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Operating Humidity | 0 – 95% (non-condensing) |
Storage Temperature | 5 – 113 °F (-15 – 45 °C) |
Maximum Operating Elevation | 10,000 ft (3,000 m) |
Maximum Storage Elevation | 50,000 ft (15,000 m) |
Certifications | |
Safety | UL1778
cUL 107.1 FCC DOC Class B |
Environmental | RoHS Compliant |
Warranty | |
Product Warranty | 3 Years Limited |
Connected Equipment Guarantee | Lifetime |
CEG Amount | $400,000 |
The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel® Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).
Safe Shutdown
The PowerPanel® Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.
Programmable Outlet Control
Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.
GreenPower UPS™ Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.
Our patented Bypass Design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.
In the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.
Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.
During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.
In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR® program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.
To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.
Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.
Automatic Voltage Regulation (AVR) in line interactive UPS systems stabilizes the incoming AC signal to maintain output power at a nominal 120 volts by controlling high and low voltages without resorting to battery power. This significantly increases battery life and lessens the likelihood of data loss, memory freezes, and system crashes.
How AVR Works in a Line Interactive UPS
A line interactive UPS includes an AVR autotransformer a special type of transformer designed to switch between powered coils of wire in response to variances in utility power input, thereby increasing or decreasing the magnetic field and the resulting output voltage to connected equipment.
This type of UPS tolerates undervoltage brownouts and overvoltage surges without consuming backup battery power by automatically selecting different power taps on the AVR autotransformer. During normal operation, incoming AC power bypasses the autotransformer (where voltage highs and lows are controlled) while also charging the battery. When the incoming voltage falls below the AVR range, the UPS switches to battery backup, and the DC-AC inverter circuitry is engaged. Power will continue to be supplied by the battery-inverter circuit until incoming voltage returns to the range manageable by the AVR.