4 Strand, OCC DX Series, Outdoor Burial, CST Armored DX Distribution, Singlemode 9/125
Reference Previous Part Number: DX04-050D-SLX/900-CST
Note: This item may require 24 hours for cut and prep before shipping.
Cable Charecteristics: D-Series Distribution Riser Cables
|
Tensile Load |
Menimum Bend Radius |
|
Diameter |
Weight |
Installation |
Operational |
Installation |
Long Term |
Fiber Count |
Part Number |
mm/(in) |
kg/km (lbs/1,000) |
N (lbs) |
N (lbs) |
cm (in) |
cm (in) |
4 |
DX004DSLX9KAA2 |
5.1 (0.20) |
24 (16) |
1,400 (310) |
450 (100) |
7.7 (3.0) |
5.1 (2.0) |
DISTRIBUTION SERIES FIBER OPTIC CABLE TYPE OFNR RISER PRODUCT SPECIFICATIONS
Applications
- Indoor/Outdoor tight-bound tight-buffered design allows cables to be installed in intra-building campus locations without costly transitions between cable types
- Ideal configuration for a single termination point reguiring multiple fibers
Features
- High performance components and construction
- Cable materials are Indoor/Outdoor UL-listed OFNR and UV, water and fungus resistant
- UL Listed in accordance with NEC section 770.179 (b) for use in vertical runs in building riser shafts or from floor to floor
- Wide operating temperature range of -40°C to +85°C
- Helically stranded core for greater flexibility and mechanical protection of the optical fibers
- High strength-to-weight ratio
- 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends
- Can be armored for additional protection in direct burial and aerial installations
- Interlocking armor can be applied to cables as an alternative to conduit installation
Cost savings
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
- No need to splice Outdoor cable to Indoor cable at building entrance
- High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
|
Indoor/Outdoor |
Operating Temperature |
-40°C to +85°C |
Storage Temperature |
-55°C to +85°C |
Installation Temperature (cable temp.) |
-10°C to +60°C |
Flame Retardancy |
UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) |
Impact Resistance |
1,500 impacts |
Crush Resistance |
1,800 N/cm |
Flex Resistance |
2,000 Cycles |
Note: These specifications are subject to change without prior notification.