OCC, DX, Distribution Series, 4-Strand, 900um Tight Buffered, Outdoor Burial, CST Armored, OS2, 9/125, Singlemode, Black Jacket (Priced Per Foot)

Sale
click to zoom in

OCC, DX, Distribution Series, 4-Strand, 900um Tight Buffered, Outdoor Burial, CST Armored, OS2, 9/125, Singlemode, Black Jacket (Priced Per Foot)

Item#:
DX004DSLX9KAA2
$1.34
$1.22
Weight:
0.19 LBS
Minimum Purchase:
1000 units
Customer Service

Need Help?

Speak to one of our experts.

DX004DSLX9KAA2 - 4-Strand, OCC DX Series, Outdoor Burial, CST Armored DX Dist., Singlemode 9/125 OS2

OCC, DX, Distribution Series, 4-Strand, 900um Tight Buffered, Outdoor Burial, CST Armored, OS2, 9/125, Singlemode, Black Jacket (Priced Per Foot)

$1.34
$1.22

4 Strand, OCC DX Series, Outdoor Burial, CST Armored DX Distribution, Singlemode 9/125

Reference Previous Part Number: DX04-050D-SLX/900-CST

Note: This item may require 24 hours for cut and prep before shipping.

 

Cable Charecteristics: D-Series Distribution Riser Cables

  Tensile Load Menimum Bend Radius
  Diameter Weight Installation Operational Installation Long Term
Fiber Count Part Number mm/(in) kg/km (lbs/1,000) N (lbs) N (lbs) cm (in) cm (in)
4 DX004DSLX9KAA2 5.1 (0.20) 24 (16) 1,400 (310) 450 (100) 7.7 (3.0) 5.1 (2.0)

 

 

DISTRIBUTION SERIES FIBER OPTIC CABLE TYPE OFNR RISER PRODUCT SPECIFICATIONS

Applications

  • Indoor/Outdoor tight-bound tight-buffered design allows cables to be installed in intra-building campus locations without costly transitions between cable types
  • Ideal configuration for a single termination point reguiring multiple fibers

Features

  • High performance components and construction
  • Cable materials are Indoor/Outdoor UL-listed OFNR and UV, water and fungus resistant
  • UL Listed in accordance with NEC section 770.179 (b) for use in vertical runs in building riser shafts or from floor to floor
  • Wide operating temperature range of -40°C to +85°C
  • Helically stranded core for greater flexibility and mechanical protection of the optical fibers
  • High strength-to-weight ratio
  • 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends
  • Can be armored for additional protection in direct burial and aerial installations
  • Interlocking armor can be applied to cables as an alternative to conduit installation

Cost savings

  • 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
  • No need to splice Outdoor cable to Indoor cable at building entrance
  • High crush resistance may eliminate the need for innerduct

Mechanical and Environmental Performance

  Indoor/Outdoor
Operating Temperature -40°C to +85°C
Storage Temperature -55°C to +85°C
Installation Temperature (cable temp.) -10°C to +60°C
Flame Retardancy UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232)
Impact Resistance 1,500 impacts
Crush Resistance 1,800 N/cm
Flex Resistance 2,000 Cycles

Note: These specifications are subject to change without prior notification.