2 Strand, OCC BX Series Breakout, Indoor/Outdoor, OFNR Riser, Multimode 50/125 OM3
Reference Previous Part Number:BX02-070D-ALT/900-OFNR
Note: This item may require 24 hours for cut and prep before shipping.
CABLE CHARACTERISTICS: B-SERIES BREAKOUT RISER CABLES (WITH 2.5MM SUBCABLES)
|
Tensile Load |
Menimum Bend Radius |
|
Diameter |
Weight |
Installation |
Operational |
Installation |
Long Term |
Fiber Count |
Part Number |
mm/(in) |
kg/km (lbs/1,000) |
N (lbs) |
N (lbs) |
cm (in) |
cm (in) |
2 |
BX002DALT9KR |
7.0 (0.28) |
41 (28) |
1,200 (270) |
500 (110) |
10.5 (4.1) |
7.0 (2.8) |
BREAKOUT SERIES FIBER OPTIC CABLE TYPE OFNR RISER PRODUCT SPECIFICATIONS
Applications
- Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary
- Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired
Features
- High performance components and construction
- UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
- Most rugged and easy to install cable design for enterprise cabling applications
- Core-Locked™ outer jacket design for installation survivability, long-term, trouble free service
- Ideal for use in long, vertical installations
- 2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)
- Subcabled fiber is environmentally and mechanically protected
- Ideal for use in point-to-point runs in adverse environments
- Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
- Design is ideal for direct pulling with mesh grips
- Cable materials are Indoor/Outdoor UV, water and fungus resistant
- Wide operating temperature range of -40°C to +85°C
- High performance 900 µm tight-buffered coating on each optical fiber for environmental and mechanical protection
- Interlocking armor can be applied to cables as an alternative to conduit installation
Cost savings
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber. See page PI-6 for typical termination approach.
- Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
- High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
|
Indoor/Outdoor |
Operating Temperature |
-40°C to +85°C |
Storage Temperature |
-55°C to +85°C |
Installation Temperature (cable temp.) |
-10°C to +60°C |
Flame Retardancy |
UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) |
Impact Resistance |
1,500 impacts |
Crush Resistance |
2,200 N/cm |
Flex Resistance |
2,000 Cycles |
Note: Optical Cable Corporation reserves the right to change this specification without prior notification.