Optical Cable Corporation
Speak to one of our experts.
Offering the durability you expect from OCC, these distribution cables provide all of the indispensable elements needed for Indoor and Indoor/Outdoor commercial applications, while providing great value. Manufactured with
Indoor/Outdoor grade low smoke PVC for plenum applications.
Applications
Features
Indoor ("T" Jacket)
Cable Characteristics
JACKET COLOR |
Aqua, Black, Orange, and Yellow |
JACKET MATERIAL |
Indoor / Outdoor Low Smoke PVC |
BUFFER MATERIAL |
Low Smoke PVC |
FIBER COUNT |
DIAMETER MM (IN) |
WEIGHT KG/KM (LBS/1,000FT) |
TENSILE LOAD |
MINIMUM BEND RADIUS |
|||
INSTALLATION N (LBS) |
OPERATIONAL N (LBS) |
INSTALLATION CM (IN) |
LONG-TERM CM (IN) |
||||
2 |
3.8 (0.15) |
15 (10) |
660 (150) |
180 (40) |
5.7 (2.3) |
3.8 (1.5) |
|
4 |
4.5 (0.18) |
18 (12) |
1200 (270) |
400 (50) |
6.7 (2.6) |
4.5 (1.8) |
|
6 |
4.7 (0.19) |
22 (15) |
1400 (310) |
450 (100) |
7.1 (2.8) |
4.7 (1.9) |
|
8 |
5.7 (0.22) |
37 (25) |
1600 (360) |
525 (120) |
8.6 (3.4) |
5.7 (2.2) |
|
10 |
6.1 (0.24) |
44 (29) |
1800 (400) |
600 (135) |
9.1 (3.6) |
6.1 (2.4) |
|
12 |
6.2 (0.24) |
40 (27) |
1800 (400) |
600 (135) |
9.3 (3.7) |
6.2 (2.4) |
|
18 |
6.7 (0.27) |
54 (36) |
1800 (400) |
600 (135) |
10.1 (4.0) |
6.7 (2.7) |
|
24 |
8.1 (0.32) |
66 (44) |
3000 (670) |
1000 (220) |
12.2 (4.8) |
8.1 (3.2) |
Mechanical and Environmental Performance
Operating Temperature | -40°C to +70°C |
Storage Temperature | -40°C to +70°C |
Installation Temperature (cable temp.) | -0°C to +60°C |
Flame Retardancy | UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
FLEX RESISTANCE (TIA-455-104) | 1,000 Cycles |
CRUSH RESISTANCE (TIA-455-41) | 1,500 N/cm |