OCC, DX, Distribution Series, 36-Strand, 900um Tight Buffered, Indoor/Outdoor, ILA Armored, Chemical Resistant OFNP Plenum Rated, OS2, 9/125, Singlemode, Yellow Jacket
Reference Previous Part Number: DX36-080K-SLX/900-OFCP-IAK
Note: This item may require 24 hours for cut and prep before shipping.
DX-Series Distribution – Chemical Resistant – Aluminum Interlocking Armor (ILA) – Plenum Rated Cables
Installation zone RECOMMENDATION
- Ideal for industrial and other installations requiring a metallic conduit
- Interlocking pre-loaded armor may eliminate the need for conduit, reducing installation costs
Applications
- Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces
- Ideal configuration for a single termination point requiring multiple fibers
- Aluminum interlocking armor with fluoropolymer overjacket
- Interlocking armor can be easily removed leaving an intact inner cable
- Greater flexibility than corrugated steel armored (CST) cables
- Ideal for locations that require conduit for cable protection
- Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments
Features
- UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
- Fluorpolymer inner and outer jackets
- Cable materials are Indoor/Outdoor UL-Listed OFCP and also UV, water, chemical, and fungus resistant
- Jacket is highly chemical resistant for installation in harsh industrial environments
- High performance tight-buffered coating on each fiber for environmental and mechanical protection
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
- Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
- Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments.
Characteristics
Characteristic |
Plenum (Indoor/Outdoor) |
Operating Temp |
-40°C to +85°C |
Storage Temp |
-40°C to +85°C |
Install Temp |
0°C to +60°C |
Flame Retardancy |
UL Listed Type OFCP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Crush Resist |
650 N/cm |
Impact Resist |
20 impacts |
Flex Resist |
25 cycles |
Jacket Type |
K |
Standards
OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
- ANSI/NFPA 262
- ICEA-S-83-596
- UL 1651
Specifications
ILA Plenum ("K" jacket)
|
Tensile Load |
Minimum Bend Radius |
|
Fiber Count |
Part Number |
Diameter mm (in) |
Weight kg/km (lbs/1,000ft) |
Installation N (lbs) |
Operation N (lbs) |
Installation cm (in) |
Longer Term cm (in) |
|
2 |
DX002K***9*PI6 |
13.1 (0.52) |
175.0 (118.0) |
1,350 (300) |
400 (90) |
26.2 (10.3) |
19.7 (7.8) |
|
4 |
DX004K***9*PI6 |
13.1 (0.52) |
175.0 (118.0) |
1,350 (300) |
400 (90) |
26.2 (10.3) |
19.7 (7.8) |
|
6 |
DX006K***9*PI6 |
13.1 (0.52) |
175.0 (118.0) |
1,350 (300) |
400 (90) |
26.2 (10.3) |
19.7 (7.8) |
|
12 |
DX012K***9*PI6 |
14.1 (0.56) |
209.0 (140.0) |
1,350 (300) |
400 (90) |
28.2 (11.1) |
21.2 (8.3) |
|
18 |
DX018K***9*PI6 |
14.1 (0.56) |
209.0 (140.0) |
1,350 (300) |
400 (90) |
28.2 (11.1) |
21.2 (8.3) |
|
24 |
DX024K***9*PI6 |
16.1 (0.63) |
264.0 (177.0) |
1,350 (300) |
400 (90) |
32.2 (12.7) |
24.2 (9.5) |
|
36 |
DX036KSLX9YPI6 |
16.1 (0.63) |
273.0 (183.0) |
1,350 (300) |
400 (90) |
32.2 (12.7) |
24.2 (9.5) |
|
48 |
DX048K***9*PI6 |
17.7 (0.70) |
320.0 (215.0) |
1,350 (300) |
400 (90) |
35.4 (13.9) |
26.6 (10.5) |
|
72 |
DX072K***9*PI6 |
20.7 (0.81) |
456.0 (306.0) |
1,350 (300) |
400 (90) |
41.4 (16.3) |
31.1 (12.2) |
|
96 |
DX096K***9*PI6 |
21.7 (0.85) |
511.0 (343.0) |
1,350 (300) |
400 (90) |
43.4 (17.1) |
32.6 (12.8) |
|