CAT6A 23AWG/4PAIR 10G CMP SHIELDED F/UTP
23 AWG 4 Pair F/UTP 10G Category 6A cable tested to ANSI/TIA 568-C.2 for 10Gbps@500Mhz premium grade, high performancefor top level network cabling for maximumheadroom and bandwidth. Available in WoodReel for easier installation.
![6ASHDCMPRx - Cat6A Shielded, F/UTP, Plenum, 10G, 23awg/4pr, 1000' - Image 2](https://cdn11.bigcommerce.com/s-4nx1nz8zp1/product_images/uploaded_images/moved-1247b414aa0783bb371f42bb02c21e16.png)
![6ASHDCMPRx - Cat6A Shielded, F/UTP, Plenum, 10G, 23awg/4pr, 1000' - Image 3](https://cdn11.bigcommerce.com/s-4nx1nz8zp1/product_images/uploaded_images/moved-f9cd883efeed7c60c694b1dcb9430f9a.png)
FEATURES AND BENEFITS
- Category 6A performs at improved specifications, particularly in the area of alien crosstalk. Category 6A make use of their higherstandards by allowing full 10GBASE-T transmission speeds of up to 10Gbps, at 500MHzof signal bandwidth, over 100 meters (330 ft)
- Improved cable temperature rating (900CPlenum) for greater protection againstincreased operating temperatures and forhigh-wattage applications
- The internal separator optimizes each pairfor superior electrical perfomance and maintains flexibility. This unique spline stabilizeseach pair to create a smaller, round cableprofile
APPLICATIONS
- IEEE 802.3 10G Base-T, 1000Base-T, 100Base-TX, 10Base-T, PoE, PoE+
- ANSI/TIA 854: 1000Base-TX
- CDDI, Token Ring, ATM
- Digital Video
- Broadband and Baseband Analog Video
STANDARD COMPLIANCES
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class EI)
- ICEA 8-102-700 (Category 6 or 5E)
- REACH Compliant
- CPR Compliant (Fully Comply to 305/201 1 & EN 50575:2014-09)
- RoHS Compliant Directive 2002/95/EG
ELECTRICAL PERFORMANCE
ACRF - Attenuation to Crosstalk Ratio - Far End (dB/100m)
NEXT - Near End Crosstalk (dB/100m)
ACR - Attenuation to Crosstalk Ratio (dB/100m)
PSNEXT - Power Sum Near End Crosstalk (dB/100m)
ELFEXT - Equal Level Far End Crosstalk (dB/100m)
PSELFEXT - Power Sum Equal Leverl Far End Crosstalk (dB/100m)
RL - Return Loss (dB)
TCL - Transverse Conversion Loss (dB/100m)
ATT - Attenuation (dB/100m)
![6ASHDCMPRx - Cat6A Shielded, F/UTP, Plenum, 10G, 23awg/4pr, 1000' - Image 4](https://cdn11.bigcommerce.com/s-4nx1nz8zp1/product_images/uploaded_images/moved-a9ac1f90a1ae73fbd6ef05dcd1bf3d93.png)
![6ASHDCMPRx - Cat6A Shielded, F/UTP, Plenum, 10G, 23awg/4pr, 1000' - Image 5](https://cdn11.bigcommerce.com/s-4nx1nz8zp1/product_images/uploaded_images/moved-d5796a4fc7f66f5ab197ddbd29fef68f.png)
![6ASHDCMPRx - Cat6A Shielded, F/UTP, Plenum, 10G, 23awg/4pr, 1000' - Image 6](https://cdn11.bigcommerce.com/s-4nx1nz8zp1/product_images/uploaded_images/moved-d7d44902a9f9cf9e7cab4ba77d75a98b.png)