Product Overview
The CyberPower PR2000RTXL2UCN Smart App Sinewave UPS provides reliable battery backup, surge protection, and clean sine wave power for servers, networking equipment, and sensitive electronics. Its line-interactive topology and rack/tower convertible design deliver flexible power protection for business networks, IT infrastructure, and critical electronic systems.
Designed for reliable operation and convenient maintenance, the PR2000RTXL2UCN features advanced battery management, Automatic Voltage Regulation (AVR), and expandable backup runtime. A factory-installed RMCARD205 network management card enables remote UPS monitoring and control, while compatibility with the BP48VP2U02 Extended Battery Module allows additional runtime during power outages.
Backed by a three-year warranty and a $400,000 Connected Equipment Guarantee, the PR2000RTXL2UCN provides dependable protection for business-critical equipment.
Key Features
Battery Backup
Supplies temporary power during outages, allowing equipment to shut down safely while reducing data loss and hardware stress.
Line-Interactive Topology with Automatic Voltage Regulation (AVR)
Corrects minor voltage fluctuations, including brownouts and overvoltage conditions, without switching to battery power.
Sine Wave Output
Delivers clean, consistent power for sensitive electronics and Active PFC power supplies.
Battery Equalization Technology
Balances battery voltages during charging to improve performance and extend battery life.
Fast Charge Technology
Uses built-in charging technology to restore UPS and compatible external battery capacity more quickly.
Rotatable Multifunction LCD Panel
Tilts for convenient viewing and rotates 90° for tower installation. Displays 47 settings for UPS status, configuration, management, and testing.
Toolless Battery Panel Access
Features a removable front panel with side latches and hand-loosened captive screws for quick battery replacement.
RMCARD205 Factory Installed
Enables remote UPS monitoring, management, and control through a web browser, command-line interface (CLI), or network management system (NMS).
Extended Battery Module Compatibility
Supports the BP48VP2U02 Extended Battery Module to increase backup runtime during
What’s In The Box
UPS System, Faceplate, UPS User Manual, 2-Post Rack Mounting Kit, 4-Post Rail Rack Mounting Kit, Tower Mounting Kit, Emergency Power Off Cable (gray), and USB A+B Type Cable
WARNING:
This product can expose you to chemicals including Styrene, which are known to the State of California to cause cancer, and Bisphenol A (BPA), which are known to the State of California to cause birth defects or other reproductive harm.
| General | |
|---|---|
| Active PFC Compatible | Yes |
| Energy Saving | GreenPower UPS™ Bypass Technology |
| Energy Star Certified | Yes |
| UPS Topology | Line-Interactive |
| Battery | |
| Battery Quantity | 4 |
| Battery Size | 12V / 9AH |
| Battery Type | Sealed Lead-Acid |
| Extended Battery Module | BP48VP2U02 |
| Extended Battery Option | Yes |
| Hot Swappable | Yes |
| Replacement Battery Cartridge | RB1290X4J |
| Replacement Battery Cartridge Quantity | 1 |
| Runtime at Full Load | 4.3 Minutes |
| Runtime at Half Load | 12.2 Minutes |
| Typical Recharge Time | 3 hrs (0% to 90% charged) |
| User Replaceable | Yes |
| Dimensions | |
| Physical Dimensions – (WxHxD) (cm) | 43.43 x 8.64 x 50.04 (cm) |
| Physical Dimensions – (WxHxD) (in) | 17.1 x 3.4 x 19.7 (in) |
| Physical Dimensions – (WxHxD) (mm) | 434 x 86 x 500 (mm) |
| Weight (kg) | 33.79 |
| Weight (lb) | 74.5 |
| Dimensions – Shipping | |
| Shipping – Weight (kg) | 40.19 |
| Shipping – Weight (lb) | 88.6 |
| Shipping Dimensions – (WxHxD) (cm) | 56.13 x 27.43 x 61.98 (cm) |
| Shipping Dimensions – (WxHxD) (in) | 22.1 x 10.8 x 24.4 (in) |
| Shipping Dimensions – (WxHxD) (mm) | 561.34 x 274.32 x 619.76 (mm) |
| Input | |
| Adjustable Voltage Range | 70 – 155 Vac |
| Circuit Breaker | 20A |
| Cord Length (ft) | 10 |
| Frequency Range | 47 – 63 Hz |
| Input Voltage | 100-125Vac |
| Input Voltage Range | 75 – 149 Vac |
| Plug Style | Right Angle, 0° Offset |
| Plug Type | NEMA 5-20P |
| Output | |
| Automatic Voltage Regulation | Double boost, single buck |
| On Battery Frequency | 50/60Hz +/- 1% |
| On Battery Voltage | 100/110/120/125Vac ± 5% |
| On Battery Waveform | Sine wave |
| Outlet Type | NEMA 5-20R |
| Outlets – Battery & Surge Protected | 8 |
| Outlets – Critical Load | 4 |
| Outlets – Total | 8 |
| Overload Protection | Internal Circuitry Limiting, Circuit Breaker |
| Rated Power Factor | 1 |
| Transfer Time | 6ms typical |
| VA | 2000 |
| Watts | 2000 |
| Surge Protection & Filtering | |
| EMI/RFI Filtration | Yes |
| Surge Suppression | 2430 J |
| Management & Communications | |
| Audible Alarms | Battery Mode, Low Battery, Overload, Overcharge, Overheat |
| Emergency Power Off (EPO) Port | Yes |
| HID Compliant USB Port | Yes |
| LCD | Multifunction LCD |
| LED Indicators | Power on, Line mode, Battery mode, Fault |
| Management Cable | USB Cable, EPO Cable |
| SNMP / HTTP Remote Monitoring | Yes – pre-installed RMCARD205, Yes with built-in RJ45 Ethernet connection cloud port |
| Serial Port | Yes, Yes 1 Dry Contact |
| Software | PowerPanel® Business Edition |
| Physical | |
| Color | Black |
| Enclosure Construction | Metal |
| Form Factor | Rack/Tower |
| Rack Size | 2U |
| Environmental | |
| Audible noise at 1m from surface of unit | 57.5 dBA |
| Online Thermal Dissipation | 130 BTU/hr |
| Operating Elevation | 0-9843 ft |
| Storage Elevation | 0-49213 ft |
| Operating Relative Humidity | 0 – 95% (non-condensing) |
| Operating Temperature | 32 °F to 104°F (0°C to 40°C) |
| Storage Relative Humidity | 0 – 95% |
| Storage Temperature | 5°F to 113°F (-15°C to 45°C) |
| Certifications | |
| Environmental | RoHS Compliant |
| Safety | UL1778, CSA C22.2 No 107.3, FCC Class B, VCCI |
| Warranty | |
| CEG Amount | $400,000 |
| Connected Equipment Guarantee | Lifetime |
| Product Warranty | 3 Years Limited |
Feature Focus
GreenPower UPS™ Technology: Bypass Design
CyberPower's patented GreenPower UPS™ Bypass Design improves energy efficiency by allowing utility power to bypass the transformer and Automatic Voltage Regulation (AVR) circuitry when incoming power is stable.
This reduces energy consumption, heat generation, and operating costs while maintaining reliable power protection.
Higher Capacity UPS for Longer Runtimes
Selecting the appropriate UPS capacity requires evaluating the connected equipment's total power requirements (VA/Watts) and desired backup runtime.
Choosing a UPS with approximately 30–35% additional capacity can provide room for future equipment expansion, reduce the risk of overloads, and potentially extend battery runtime.
Actual runtime depends on the connected load, battery configuration, and operating conditions.
Efficient Remote Management
The PR2000RTXL2UCN supports centralized monitoring and power management through PowerPanel® Business Edition software and its factory-installed RMCARD205 network management card.
Administrators can monitor UPS performance, receive alerts, manage settings, and coordinate equipment shutdowns through supported network interfaces.
Safe ShutdownPowerPanel® Business Edition supports automated shutdown of connected servers and workstations during extended outages. Additional capabilities include event logging, reporting, alerts, and notifications.
Programmable Outlet ControlOn supported configurations, programmable outlet groups allow administrators to prioritize critical equipment, extend available runtime, and sequence equipment startup after power restoration.
Sine Wave Power
The PR2000RTXL2UCN delivers sine wave output designed to support sensitive electronic equipment, including systems with Active Power Factor Correction (PFC) power supplies.
Its sine wave output provides a compatible power source during battery operation, helping reduce the risk of unexpected shutdowns associated with incompatible simulated sine wave UPS output.
Battery Equalization Technology
CyberPower's Battery Equalization Technology helps maintain consistent voltage levels across batteries in a multi-battery string.
By reducing voltage imbalances, this charging technology supports reliable battery performance, improved runtime consistency, and longer battery service life, potentially reducing replacement costs.