2 Strand OCC DX Series 900 µm Tight Buffered, Indoor/Outdoor Distribution, OFNR Riser, Multimode 62.5/125
Reference Previous Part Number:BX24-130K-WLS/900-OFNP
Note: This item may require 24 hours for cut and prep before shipping.
Cable Charecteristics: B-Series Breakout Plenum Cables (with 2.0mm subcables)
|
Tensile Load |
Menimum Bend Radius |
|
Diameter |
Weight |
Installation |
Operational |
Installation |
Long Term |
Fiber Count |
Part Number |
mm/(in) |
kg/km (lbs/1,000) |
N (lbs) |
N (lbs) |
cm (in) |
cm (in) |
24 |
BX024KWLS9OP |
14.2 / (0.56) |
221 / (148) |
7200 / (1620) |
1800 / (400) |
21.3 / (8.4) |
21.3 / (8.4) |
Breakout Series Fiber Optic Cable Type OFNP plenum Product Specifications
Applications:
- Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are required
- Installed in ducts, plenums, and air handling spaces
- Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired
Features:
- High performance components and construction
- UL Listed in accordance with NEC sections 770.179(a) for use in ducts, plenums and air-handling spaces
- Most rugged and easy to install cable design for enterprise cabling applications
- Standard 2.0mm subcables can be directly terminated with standard connectors. 2.5mm and 2.9mm subcable sizes are also available
- Subcabled fiber is environmentally and mechanically protected
- Ideal for use in point-to-point runs in adverse environments
- Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
- Design is ideal for direct pulling with mesh grips
- Cable materials are Indoor/Outdoor - UV, water and fungus resistant
- Wide operating temperature range of -40°C to +85°C
- High performance 900 micron tight buffered coating on each optical fiber for environmental and mechanical protection
- Jacket highly chemical resistant for installation in harsh industrial environments
- Interlocking armor can be applied to cables as an alternative to conduit installation
- 2 to 60 fibers
Cost Savings:
- Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
- 900 µm eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
- High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
Note:Optical Cable Corporation reserves the right to Change This specifications without prior notification.
|
Indoor/Outdoor (K) |
Operating Temperature |
-40°C to +85°C |
Storage Temperature |
-40°C to +85°C |
Installation Temperature (cable temp.) |
-0°C to +60°C |
Flame Retardancy |
UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Impact Resistance |
1,000 impacts |
Crush Resistance |
2,100 N/cm |
Flex Resistance |