8 Strand, OCC DX Series, Outdoor Burial, CST Armored DX Distribution, Multimode 62.5/125
Reference Previous Part Number: DX08-060D-WLS/900-CST
Note: This item may require 24 hours for cut and prep before shipping.
 
Cable Charecteristics: D-Series Distribution Riser Cables
|   | 
Tensile Load | 
Menimum Bend Radius | 
|   | 
Diameter | 
Weight | 
Installation | 
Operational | 
Installation | 
Long Term | 
| Fiber Count | 
Part Number | 
mm/(in) | 
kg/km (lbs/1,000) | 
N (lbs) | 
N (lbs) | 
cm (in) | 
cm (in) | 
| 8 | 
DX008DWLS9KAA2 | 
5.9 (0.23) | 
34 (23) | 
1,600 (360) | 
525 (120) | 
8.9 (3.5) | 
5.9 (2.3) | 
 
 
 
DISTRIBUTION SERIES FIBER OPTIC CABLE TYPE OFNR RISER PRODUCT SPECIFICATIONS
Applications
- Indoor/Outdoor tight-bound tight-buffered design allows cables to be installed in intra-building campus locations without costly transitions between cable types
 
- Ideal configuration for a single termination point reguiring multiple fibers
 
Features
- High performance components and construction
 
- Cable materials are Indoor/Outdoor UL-listed OFNR and UV, water and fungus resistant
 
- UL Listed in accordance with NEC section 770.179 (b) for use in vertical runs in building riser shafts or from floor to floor
 
- Wide operating temperature range of -40°C to +85°C
 
- Helically stranded core for greater flexibility and mechanical protection of the optical fibers
 
- High strength-to-weight ratio
 
- 2-144 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends
 
- Can be armored for additional protection in direct burial and aerial installations
 
- Interlocking armor can be applied to cables as an alternative to conduit installation
 
Cost savings
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
 
- No need to splice Outdoor cable to Indoor cable at building entrance
 
- High crush resistance may eliminate the need for innerduct
 
Mechanical and Environmental Performance
|   | 
Indoor/Outdoor | 
| Operating Temperature | 
-40°C to +85°C | 
| Storage Temperature | 
-55°C to +85°C | 
| Installation Temperature (cable temp.) | 
-10°C to +60°C | 
| Flame Retardancy | 
UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) | 
| Impact Resistance | 
1,500 impacts | 
| Crush Resistance | 
1,800 N/cm | 
| Flex Resistance | 
2,000 Cycles | 
Note: These specifications are subject to change without prior notification.