Speak to one of our experts.
OCC, DX, Distribution Series, 12-Strand, 900um Tight Buffered, Indoor/Outdoor, Chemical Resistant OFNP Plenum Rated, OM2, 50/125, Multimode, Orange Jacket
Reference Previous Part Number:DX12-060K-ALS/900-OFNP
Note: This item may require 24 hours for cut and prep before shipping.
This plenum distribution fiber cable is used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces. It's ideal for configurations requiring a single termination point with multiple fibers. The plenum distribution fiber optic cable uses high performance components and construction and is UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces.
Multimode Fiber Information
Multi-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond.
Indoor/Outdoor ("K" Jacket)
Optical Cable Corporation Indoor/Outdoor tight buffered fiber optic cables meet the functional requirements of the following standards:
Characteristic | Plenum Indoor/Outdoor (K) |
---|---|
Operating Temp | -40°C to +85°C |
Storage Temp | -40°C to +85°C |
Install Temp | 0°C to +60°C |
Flame Retardancy | UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Crush Resist | 1500 N/cm (TIA/EIA-455-41A) |
Impact Resist | 1000 impacts (EIA/TIA-455-25A) |
Flex Resist | 1000 cycles (TIA/EIA-455-104A) |
Jacket Type | K |
Tensile Load | Minimum Bend Radius | ||||||||
---|---|---|---|---|---|---|---|---|---|
Fiber Count | Part Number | Part Number Configurator | Diameter mm (in) |
Weight kg/km (lbs/1,000ft) |
Installation N (lbs) |
Operation N (lbs) |
Installation cm (in) |
Longer Term cm (in) |
|
2 | DX002K***9*P | 4.8 (0.19) |
24.0 (16.0) |
1,400 (310) |
450 (100) |
7.2 (2.8) |
7.2 (2.8) |
||
4 | DX004K***9*P | 4.8 (0.19) |
24.0 (16.0) |
1,400 (310) |
450 (100) |
7.2 (2.8) |
7.2 (2.8) |
||
6 | DX006K***9*P | 4.8 (0.19) |
24.0 (16.0) |
1,400 (310) |
450 (100) |
7.2 (2.8) |
7.2 (2.8) |
||
8 | DX008K***9*P | 5.1 (0.20) |
30.0 (20.0) |
1,600 (360) |
525 (120) |
7.7 (3.0) |
7.7 (3.0) |
||
10 | DX010K***9*P | 5.7 (0.22) |
38.0 (26.0) |
1,800 (400) |
600 (135) |
8.6 (3.4) |
8.6 (3.4) |
||
12 | DX012K***9*P | 6.5 (0.26) |
45.0 (30.0) |
2,700 (600) |
900 (200) |
9.8 (3.9) |
9.8 (3.9) |
||
18 | DX018K***9*P | 6.5 (0.26) |
42.0 (28.0) |
2,700 (600) |
900 (200) |
9.8 (3.9) |
9.8 (3.9) |
||
24 | DX024K***9*P | 8.3 (0.33) |
71.0 (46.0) |
3,000 (670) |
1,000 (220) |
11.8 (4.6) |
11.8 (4.6) |
||
30 | DX030K***9*P | 8.2 (0.32) |
81.0 (53.0) |
3,000 (670) |
1,000 (220) |
12.4 (4.9) |
12.4 (4.9) |
||
36 | DX036K***9*P | 8.3 (0.33) |
80.0 (53.0) |
3,000 (670) |
1,000 (220) |
12.4 (4.9) |
12.4 (4.9) |
||
48 | DX048K***9*P | 9.6 (0.38) |
104.0 (70.0) |
4,200 (940) |
1,400 (310) |
14.3 (5.6) |
14.3 (5.6) |
||
60 | DX060K***9*P | 10.7 (0.42) |
129.0 (87.0) |
4,800 (1,080) |
1,600 (360) |
16.1 (6.3) |
16.1 (6.3) |
||
72 | DX072K***9*P | 12.6 (0.50) |
175.0 (122.0) |
5,400 (1,200) |
1,800 (400) |
19.6 (7.7) |
19.6 (7.7) |