close
close

OCC DX 6-Strand 900um OFNP OM4, 50/125, MM, Aqua (Per Foot)

Sale
click to zoom in

OCC DX 6-Strand 900um OFNP OM4, 50/125, MM, Aqua (Per Foot)

Item#:
DX006SALE9QP
$1.21
$1.05
Condition:
New
Weight:
0.02 LBS
Minimum Purchase:
1000 units
Customer Service

Need Help?

Speak to one of our experts.

DX006SALE9QP - 6-Fiber 50/125 OM4 Ultra-Fox Indoor Distribution, Plenum Rated

OCC DX 6-Strand 900um OFNP OM4, 50/125, MM, Aqua (Per Foot)

$1.21
$1.05

Bulk Fiber, 6 Strand, Multimode, 50/125 10GB, OM4, Distribution Cable, OFNP Plenum Rated, Indoor, Tight Buffer, Aqua Outer Jacket This plenum distribution fiber cable is used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces. It's ideal for configurations requiring a single termination point with multiple fibers. The plenum distribution fiber optic cable uses high performance components and construction and is UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces. Multimode Fiber Information Multi-Mode cable commonly has a diameter in the 50-to-100 micron range (typical multimode fiber core diameters are 50 or 62.5 micrometers). Multimode fiber gives you high bandwidth at high speeds (10 to 100MBS - Gigabit to 275m to 2km) over medium distances. Light waves are dispersed into numerous paths, or modes, as they travel through the cable's core typically 850 or 1300nm. However, in long cable runs (greater than 3000 feet [914.4 meters), multiple paths of light can cause signal distortion at the receiving end, resulting in an unclear and incomplete data transmission so designers now call for single mode fiber in new applications using Gigabit and beyond. Applications: Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required for ducts, plenums, and air handling spaces Ideal configuration for a single termination point requiring multiple fibers Features: High performance components and construction High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers Lower installed cost High performance tight-buffered coating on each fiber for environmental and mechanical protection High crush resistance may eliminate the need for innerduct 900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber. UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces Indoor plenum cables eliminate the need for costly cable transitions in different installation environments Cable materials are UV, water and fungus resistant Higher fiber counts available than similar cables available by others in subgrouped configuration Jacket is highly chemical resistant for installation in harsh industrial environments Interlocking armor can be applied to cables as an alternative to conduit installation Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments 2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends Standards List: UL 1651 ANSI/NFPA 262 GR-409-CORE ICEA-S-104-696 ICEA-S-83-596 TIA-568 TIA-59 Jacket Characteristics Operating Temperature -40°C to +70°C Storage Temperature -40°C to +85°C Installation Temperature 0°C to +60° Flame Retardancy UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) Crush Resistance 1,500 N/cm Impact Resistance Per ICEA-S-83-596 Flex Resistance 1,000 cycles Specifications Diameter 4.8 mm (0.19 in) Weight 24 kg/km (16 lbs/1,000ft) Tensile Load - Installation 1400 N (310 lbs) Tensile Load - Operational 450 N (100 lbs) Minimum Bend Radius - Installation 7.2 cm (2.8 in) Minimum Bend Radius - Long Term 7.2 cm (0.2.8 in)

 

Worldwide Free Shipping
Rewards Program
Secure Shopping
30-Day Free Returns