Detector type selection guide |
|
|
|
|
There are several detector types, they have different applications based on wavelength, power, size and price so several factors must be considered. |
|
|
For further details see website: How To Choose an Optical Selector |
|
|
|
|
|
|
|
|
|
Summary of detector types |
|
|
|
|
Si = Silicon. This is suitable for wavelenghs in the visible region and 850nm (multimode). It is only used on out Si5 large area detector see below |
|
|
Ge = Germanium. This is suiable for Multimode and Singlemode wavelengths and is in our SM+MM test kits |
|
|
|
InGaAs = Indium Gallium Arsenide. This has the best response to Singlemode wavelengths and is in our SM test kits. |
|
|
|
|
|
|
|
|
Overview, the key points are highlighted. |
Detector type |
Power level |
Instrument interface |
Connectors Single fiber = SC, LC, FC, ST etc |
Ge power meter popular choice used for most MM and SM+MM applications. SC, LC, ST etc |
Ge |
-60 to +15dBm, damage +20dBm |
SC |
Single fiber |
High power Ge power meter (2 millimeter size). Specialised power meter this power level very rarely needed. |
Ge, High power |
-40 to +33dBm, damage +35dBm |
7/8" |
Single fiber |
Ge power meter with 5mm detector size. Suits MM and SM+MM applications. SC, LC, ST etc and MPO-12 and is Biggest selling MPO power meter. |
Ge, 5mm large area detector |
-40 to +15dBm, damage +20dBm |
7/8" |
Single fiber, MPO-12 |
Ge power meter with 7mm detector size. Suits MM and SM+MM applications. SC, LC, ST etc and MPO-12 / MPO-16 |
Ge, 7mm large area detector |
-40 to +15dBm, damage +20dBm |
7/8" |
Single fiber, MPO-12, MPO-16 |
InGaAs power meter, with 20dB filter. A solution for SM high power applications in practical use. SC, LC, ST etc |
InGaAs with 20dB filter |
-40 to +24dBm, damage +27dBm |
SC |
Single fiber |
InGaAs power meter, with 10dB filter. A solution for SM high power applications in practical use. SC, LC, ST etc |
InGaAs with 10dB filter |
-60 to +24dBm, damage +27dBm |
SC |
Single fiber |
InGaAs power meter popular choice for most SM applications. SC, LC, ST etc |
InGaAs no filter |
-70 to +10dBm, damage +15dBm |
SC |
Single fiber |
High power InGaAs power meter (2 millimeter size). Specialised power meter this power level very rarely needed. |
InGaAs, High power |
-40 to +33dBm, damage +35dBm |
7/8" |
Single fiber |
Ge power meter with 5mm detector size. Suits high accuracy SM applications. SC, LC, ST etc and MPO-12 |
InGaAs, 5mm large area detector |
-60 to +10dBm, damage +15dBm |
7/8" |
Single fiber, MPO-12 |
Si power meter with 5mm detector size. Suits 660nm POF fibre, and MM to 850nm. SC, LC, ST etc and MPO-12. Relatively low cost. |
Si, 5mm large area detector |
-60 to +10dBm, damage +15dBm |
7/8" |
Single fiber, MPO-12, POF connectors |